TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1. No flow. 1. Check the main shut-off valve.
2. Water leak between joints or fittings. 2. Tighten loose connections. If leak
persists, the application of hot water
will sometimes reseat improperly
applied joint compound. After 30
minutes wait and retest. A persistent
leak will necessitate reassembly and
additional sealant.
3. Insufficient water flow, shower and
eyewash.
3. Verify minimum 30 psi (2 ATM) flowing
supply line pressure.
4. Water does not drain properly. 4. Check your drain system for debris.
Check the main waste line of your
building to see if it does handle the
capacity required for the entire
drainage system.
5. Insufficient water flow on eyewash,
however, shower is sufficient.
5.a.
Verify minimum 30 psi (2 ATM) flowing
supply line pressure.
b. Probable clogging of flow control due
to inadequate line flushing. Unscrew
eye/face wash head and remove the
four screws to disassemble head.
Clean flow control and reassemble
head. See SP65 Installation Drawing
for details.
c. Remove cap located on L – Strainer
using a 3/8” allen wrench to access
and clean filter screen.
6. Eyewash or face wash streams do not
meet at desired eye level or are not
balanced.
6. Possible blocked flow control see
above solution. (Possible non-leveled
eyewash assembly.)
7. Insufficient water flow at the
showerhead, however, eyewash is
sufficient.
7.a. Probable clogging of flow control inside
shower head. Unscrew shower head
off of elbow and clean rubber flow
control.